Hazardous Location Breather Drains

    Richiesta informazioni

    Compila il form e invia una richiesta su questo prodotto





    Hazardous Location Breather Drains

    Applications: Hazardous Location Breather Drains prevent moisture build-up within hazardous approved enclosures while maintaining enclosure UL Type rating. Drains are to be used when an enclosure is subject to fluctuations in temperature which can lead to the formation of condensation and a subsequent moisture build-up. These drains allow air within an enclosure to breathe with the surrounding atmosphere, preventing condensation and any potential damage to electrical equipment.
    Features:
    Reduce corrosion that can limit the life of internal electrical and electronic components
    Prevent condensation when installations are subject to fluctuations in temperature in hazardous locations
    Effectively drain any water present within the enclosure
    Minimize moisture build-up within the enclosure by allowing air in the enclosure to breathe with surrounding atmosphere
    Position at the lowest point of an enclosure to ensure optimal draining of any moisture
    Maintain enclosure’s UL Type rating when properly installed
    Available for Increased Safety (Ex e) and Flameproof (Ex d) applications
    Specifications:
    Ex e Breather Drains:
    Type 316 stainless steel with castellated nut and nitrile O-ring
    10mm thread length
    Install in a clearance hole 0.5 to 1.0mm larger than major diameter, or in a tapped hole
    Operating temperature of -58 F (-50 C) to 185 F (85 C)
    Ex d Breather Drains:
    Type 316 stainless steel with silicone O-ring
    16mm thread length
    Install in a tapped hole
    Operating temperature of -22 F (-30 C) to 302 F (150 C)
    CONDIVIDI / SHARE

    Descrizione

    Ex e Breather Drains
    Certified for Zone 1 or 2 areas
    ATEX
    Sira 13ATEX3354U
    Ex e IIC Gb
    Ex tb IIIC Db IP66
    IECEx
    IECEx SIR 13.0138U
    Ex e IIC Gb
    Ex tb IIIC Db IP66
    cCSAus Certified Class 1 Zone 1, Ex e II, IP66, Type 4X
    NEMA/EEMAC Type 4, 4X
    IEC 60529, IP66
    Maintain enclosure Type 4, 4X rating when properly installed

    Ex d Breather Drains
    Certified for Zone 1 or 2 areas
    ATEX
    ITS13ATEX17900X
    Ex d IIC Gb
    Ex e IIC Gb
    Ex tb IIIC Db IP66
    IECEx
    IECEx ITS 13.0049X
    Ex d IIC Gb
    Ex e IIC Gb
    Ex tb IIIC Db IP66
    NEMA/EEMAC Type 4, 4X
    IEC 60529, IP66
    Maintain enclosure Type 4, 4X rating when properly installed

    Resta aggiornato

    Iscriviti alla News Letter per scoprire tutte le novità.

      Con l’iscrizione accetto l’informativa sulla privacy D.Lgs 196/2003